Thread Number: 72102
/ Tag: Vintage Dryers
GE Versatronic Dryer No Longer Heating |
[Down to Last] |
|
Post# 953513 , Reply# 1   8/19/2017 at 08:35 (2,433 days old) by DADoES (TX, U.S. of A.)   |   | |
Checkrate/Likes
 
     
|
Post# 953522 , Reply# 2   8/19/2017 at 09:00 (2,433 days old) by combo52 (50 Year Repair Tech Beltsville,Md)   |   | |
Checkrate/Likes
 
     
This dryer does not have a TF, it does have two heating elements and three thermostats and about a dozen feet of wiring in the 240 volt heating element circuit along with around 20 terminal connections in the heater circuit.
Since you just put a belt on it raise the top and make sure that all the wires on the junction block right under the top are connected properly and not burned loose etc.
It is easy to accidentally pull on of the wires loose from this junction block when working on these dryers. |