Post# 667566 , Reply# 2   3/22/2013 at 00:20 (4,025 days old) by rp2813 (Sannazay)   |   | |
Checkrate/Likes
 
     
|
Post# 667625 , Reply# 3   3/22/2013 at 11:27 (4,024 days old) by combo52 (50 Year Repair Tech Beltsville,Md)   |   | |
Checkrate/Likes
 
     
This was the 2nd KA DW that was electronically controlled, I am very familiar with this DW as we were doing factory sales and service on them when they were being sold. I have the full factory manual here in our files.
The dual heating element is the same as the heater in the 18-22 DWs that had the sump heater so even though it is NLA it should not be hard to find [ we have both new and used ones ]. The thermistor in the sump controls the heater through the computer board which in turn advances the rotary power controller that actually handles the high current for the motor, heaters etc.
These machines were very cool but had lots of problems and I do not know of any that are in regular use any longer, I do have lots of used parts for these if you want to take a chance on fixing it. John |
Post# 667709 , Reply# 5   3/22/2013 at 19:29 (4,024 days old) by combo52 (50 Year Repair Tech Beltsville,Md)   |   | |
Checkrate/Likes
 
     
|