Post# 984225   2/25/2018 at 07:45 (2,243 days old) by christfr (st louis mo)        

christfr's profile picture
you know besides a blood offering every time I work of one my tag dryers they seem to want to confuse me. sent a tag dryer to my partners house for daily use it ran fine for being close to 25 year old so last year she got a tune up with belt and rollers and a good cleaning all was fine this week the plastic blower wheel fell apart so that's an easy fix did that ran a test load all was fine. the second load no heat took the front off nothing unplugged or burnt all looks fine cant find my ohm meter to test the coil unit but I guess for what ever reason that could have died. just seems odd. is there something I'm missing or a trick I don't know.. the machine sat unplugged for a week while the part was shipped, the only thing I will say is that I also have an atlantis dryer and if I unplug that machine to use the plug for another machine that dryer wont start at all for a good day or so its really odd. any way any advice

  View Full Size



Post# 984278 , Reply# 1   2/25/2018 at 10:53 (2,243 days old) by bendixmark (Winchester Mass)        
No Heat

Either it isn't getting 220v to the machine or you have a broken wire to the element or the element has failed.Feel for a break.

Post# 984305 , Reply# 2   2/25/2018 at 15:34 (2,243 days old) by christfr (st louis mo)        

christfr's profile picture
thanks mark will check all again when I first checked nothing was loose or felt broken but will try again, did order a heat element just in case.. thanks

Post# 984312 , Reply# 3   2/25/2018 at 16:21 (2,243 days old) by rp2813 (Sannazay)        

rp2813's profile picture

The actual 220 receptacle could be bad.  This happened with the receptacle for our stove.  It had been in use since 1960.


Post# 984339 , Reply# 4   2/25/2018 at 19:59 (2,243 days old) by combo52 (50 Year Repair Tech Beltsville,Md)        
Non Heating MT Electric Dryer

combo52's profile picture

Most likley a bad element 25% chance, but there are 7 or 8 other common reasons why an electric dryer may run without heating including losing one side of the 240 volt power source [ note : there is no such thing as 220 volts in the US, only 208 and 240 volts are used in the US ] Using the term 220 volts makes one look like they don't know what they are talking about.

 

John L.


Post# 984350 , Reply# 5   2/25/2018 at 21:29 (2,242 days old) by Joefuss1984 (Little Rock, AR)        

joefuss1984's profile picture
Have heard it referred to as 220 most of my life. Whether it is it isn’t, that is what a lot of folks know it as...

Post# 984351 , Reply# 6   2/25/2018 at 21:33 (2,242 days old) by beekeyknee (Columbia, MO)        
Rude!

beekeyknee's profile picture
www.quick220.com/page/cp-voltage....

It never ceases to amaze me how nasty and superior some people can be towards others, even though they might not perceive it that way. Spelling errors and incorrect grammar seem to abound from some members. This makes some look like they don't know what they are talking about. Most of us of us let these things slide because it's not worth the trouble to point out and it just creates ill will. Maybe this is where the term "Imperial Queens" came about?


Post# 984367 , Reply# 7   2/25/2018 at 23:05 (2,242 days old) by combo52 (50 Year Repair Tech Beltsville,Md)        

combo52's profile picture

Hi Brain

 

Hundreds of people look at this site every day, using incorrect terminology just makes you look unprofessional and ill informed, you may do what ever you like and I will do the same, with out calling people names.

 

John L.


Post# 984371 , Reply# 8   2/25/2018 at 23:20 (2,242 days old) by beekeyknee (Columbia, MO)        

beekeyknee's profile picture
I didn't call you a name, John. Instead of addressing me why don't you apologize to Ralph. It would be more productive. And for the record, my name is Brian, not "Brain".

Post# 984374 , Reply# 9   2/25/2018 at 23:42 (2,242 days old) by tolivac (greenville nc)        

220V is still with us-depends on the primary tap settings on the transformer feeding your house or building.It is within the normal voltage tolerences allowed to power companies.And your dist transformer may be the last in the utility's circuit-so the voltage will be lower.The power co regulators are set to +- 10 percent tolerance.

Post# 984388 , Reply# 10   2/26/2018 at 02:01 (2,242 days old) by rp2813 (Sannazay)        

rp2813's profile picture

You know what?  I've been calling it 110 and 220 since I was a kid.  It's what my dad called it.  There were plenty of appliances with specs of 110-115 volts when I was learning things as a kid, and presumably there still are.  I have Telechron clocks that are rated for 115 volts.   I have a GE clock radio that's rated for 105-120 volts. 

 

It did occur to me that I could have used the 240 designation in my post, but since benidxmark used the same 220 figure that I tend to, I did the same.   People with only rudimentary electrical skills know what you mean whether you call it 220 or 240.  They'll both give you a serious jolt.

 

I find mistakes and typos here each and every day.  I "difidently" do.  But I have better things to do than point them out to those who made them. ;-)

 

I don't need an apology.  I'm a big boy and simply consider the source.

 

 


Post# 984450 , Reply# 11   2/26/2018 at 15:52 (2,242 days old) by christfr (st louis mo)        

christfr's profile picture
ok ok everyone calm down.. now back to the dryer, my feeling (well till I can get back to work on it come this fri) is that the heat element died the first load was fine then it was nothing but cold air.. oh well ill get there

Post# 984471 , Reply# 12   2/26/2018 at 18:01 (2,242 days old) by goatfarmer (South Bend, home of Champions)        

goatfarmer's profile picture

First thing I would check is the household fuses, or circuit breakers, to make sure the proper voltage is being supplied.



Forum Index:       Other Forums:                      



Comes to the Rescue!

The Discuss-o-Mat has stopped, buzzer is sounding!!!
If you would like to reply to this thread please log-in...

Discuss-O-MAT Log-In



New Members
Click Here To Sign Up.



                     


automaticwasher.org home
Discuss-o-Mat Forums
Vintage Brochures, Service and Owners Manuals
Fun Vintage Washer Ephemera
See It Wash!
Video Downloads
Audio Downloads
Picture of the Day
Patent of the Day
Photos of our Collections
The Old Aberdeen Farm
Vintage Service Manuals
Vintage washer/dryer/dishwasher to sell?
Technical/service questions?
Looking for Parts?
Website related questions?
Digital Millennium Copyright Act Policy
Our Privacy Policy