Do you know if you can still get the hi limit stat and where is it located? Do you happen to know the temperature s for the reg cycle and perm cycle? Thank you for any information and help you can provide |
Post# 1112085 , Reply# 5   3/19/2021 at 19:12 (1,127 days old) by combo52 (50 Year Repair Tech Beltsville,Md)   |   | |
Checkrate/Likes
 
3    
If it works on regular just use regular, the only difference is regular has a 3 minute cool Down and PP has like 7 minutes.
There is only one operating thermostat on this dryer, both cycles have the same temperature, if it really does not work on PP you have a bad heat contact in the timer and you need another timer.